Oppermann KRM-X-2 0.16
24 V AC/DC, for controlling fans and for ventilation monitoring

incl. sampling tube LKR-X 0.16 m

  • VdS approval (G219046/G219053)
  • Patented single-tube air measurement system
  • Contamination display in % and message at 70%
  • Electronic air flow control
  • Reset button externally accessible in the housing
  • Remote reset option via terminals
  • Long service life, alarm threshold tracking
  • Bus interface RS485 (only -MOD/-BAC)

Technical data

Detector type: Scattered light RM 3.3-X (ALN-E)
Power supply KRM-X-1/KRM-X-1-MOD/KRM-X-1-BAC:
230 V AC ± 10%, 50/60 Hz
Power supply KRM-X-2/KRM-X-2-MOD/KRM-X-2-BAC:
24 V AC (16 – 27.6 V AC) or 24 V DC (21.6 – 27.6 V DC)
Rated current: KRM-X-1 /KRM-X-1-MOD/KRM-X-1-BAC: 30 mA
KRM-X-2/KRM-X-2-MOD/KRM-X-2-BAC: 120 mA
Relay outputs: potential-free
Alarm relay latched: 1 changeover contact, 8 A, 250 V AC or 24 V DC
1 N.C. contact, 8 A, 250 V AC or 24 V DC
Contamination relay: 1 N.C. contact, 6 A, 250 V AC or 24 V DC
Operating temperature: -20 °C – +50 °C
Permissible flow: 1 – 20 m/s
Permissible humidity: 10 – 95% non-condensing
Protection class: IP 65
Approvals/tests: VdS approval G219046, G219053, DIN EN 54-27
LED Display: Contamination level %, flashes > 70%
LED in housing: green operation, blue no air flow, yellow fault, electronics, smoke detector defective red smoke alarm, incl. contamination > 99%, flashes when attempting to unlock if the detector chamber is not yet empty
Housing: ABS
Air measurement tube: aluminium/plastic
Shortest length 160 mm
Standard length 600 mm
Maximum length 3009 mm
Dimensions: approx. 271 x 172 x 85 mm (L x W x H)
Cable gland: 3 x M16

Function

The KRM-X duct smoke detector was developed for smoke detection in ventilation ducts. It is a combination of a smoke detector with an adapter system whose sampling tube and housing have been specially adapted for optimal airflow through the smoke detector. The multi-chamber measuring tube in the air duct transports the air within the air duct along the entire length of the tube via the detector chamber back into the air duct. If smoke is detected, the detector reacts immediately and triggers an alarm. Over time, the detector becomes contaminated. Due to the alarm threshold tracking, the sensitivity remains the same until total contamination. From 70% contamination, the detector triggers and signals this by flashing. If the detector is not replaced, a smoke alarm will occur from 99% contamination. The contamination level is indicated on a two-line LED display; at > 70%, it flashes and the "dirt" relay drops out. To demonstrate functionality, the device is equipped with electronic airflow monitoring, which illuminates a blue LED at < 1 m/s. The fault LED illuminates if the smoke detector or electronics are defective, or if the smoke detector is missing. The smoke alarm must be reset with the reset button. The function test is also possible with the same button. Actuation has the same effect as a smoke alarm. Furthermore, the same function is achieved on restart or by opening the bridge between terminals 9 and 10 (remote unlock).