KRM-X-1 0.6

KRM-X-1 0.6

SKU: 52004

Regular price €575,10 EUR
Regular price Sale price €575,10 EUR
Sale Sold out
Quantity

Oppermann KRM-X-1 0.6
230 V AC, for controlling fans and for ventilation monitoring

incl. sampling tube LKR-X 0.6 m

  • VdS approval (G219046/G219053)
  • Patented single-tube air measurement system
  • Contamination display in % and notification at 70%
  • Electronic airflow control
  • Reset button externally operable on the housing
  • Remote reset option via terminals
  • Long service life, alarm threshold tracking
  • Bus interface RS485 (only -MOD / -BAC)

Technical Data

Detector type: Scattered light RM 3.3-X (ALN-E)
Power supply KRM-X-1/KRM-X-1-MOD/KRM-X-1-BAC:
230 V AC ± 10 %, 50/60 Hz
Power supply KRM-X-2/KRM-X-2-MOD/KRM-X-2-BAC:
24 V AC (16 - 27.6 V AC) or 24 V DC (21.6 - 27.6 V DC)
Rated current: KRM-X-1 /KRM-X-1-MOD/KRM-X-1-BAC: 30 mA
KRM-X-2/KRM-X-2-MOD/KRM-X-2-BAC: 120 mA
Relay outputs: potential-free
Alarm relay latched: 1 changeover contact, 8 A, 250 V AC or 24 V DC
1 NC contact, 8 A, 250 V AC or 24 V DC
Contamination relay: 1 NC contact, 6 A, 250 V AC or 24 V DC
Operating temperature: -20 °C - +50 °C
Permissible flow: 1 - 20 m/s
Permissible humidity: 10 - 95 % non-condensing
Protection class: IP 65
Approvals/tests: VdS approval G219046, G219053, DIN EN 54-27
LED Display: Contamination level %, flashes > 70 %
LEDs in housing: green operation, blue insufficient airflow, yellow fault, electronics, smoke detector defective, red smoke alarm, incl. contamination > 99 %, flashes when attempting to unlock if the detector chamber is not yet empty
Housing: ABS
Air sampling tube: Aluminum/plastic
Shortest length 160 mm
Standard length 600 mm
Maximum length 3009 mm
Dimensions: approx. 271 x 172 x 85 mm (L x W x H)
Cable gland: 3 x M16

Function

The KRM-X duct smoke detector was developed for smoke detection in ventilation ducts. It represents a combination of a smoke detector with an adapter system whose sampling tube and housing have been specially adapted for optimal airflow through the smoke detector. The multi-chamber measuring tube in the air duct transports the air within the air duct along the entire length of the tube through the detector chamber back into the air duct. If smoke is detected, the detector reacts immediately and triggers an alarm. Over time, the detector becomes contaminated. Due to the alarm threshold tracking, the sensitivity remains the same until total contamination. From 70% contamination, the detector triggers and signals this by flashing. If the detector is not replaced, a smoke alarm will occur at 99% contamination. The degree of contamination is signaled on a two-line LED display; at > 70%, it flashes and the "dirt" relay drops out. To prove functionality, the device is equipped with an electronic airflow monitoring system, which illuminates a blue LED at < 1 m/s. The fault LED illuminates if the smoke detector or electronics are defective, as well as if the smoke detector is missing. The smoke alarm must be unlocked with the reset button. The same button can also be used for the functional test. Activating it acts like a smoke alarm. Furthermore, the same function is achieved with a restart or by opening the bridge between terminals 9 and 10 (remote unlock).